Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.
VQZ1000 VQZ2000 VQZ3000 Caution VQZ1000-S-01 (-Q) When replacing only the pilot valve assembly, use caution because it is not possible to convert to a V115 (DIN terminal) from a V111 (Grommet, L-type, M-type), or vice versa. 01 02 02 03 VQZ2000-S(-Q) VQZ3000-S(-Q) Thread type 967 EX510 Gateway System Serial Transmission System Series VQZ1000/2000/3000 Base Mounted Manifold [Option] How
How to Find the Flow Rate (at air temperature of 20 ) Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) S: Effective sectional area (mm 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow