Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.
For details about certified products conforming to international standards, visit us at www.smcworld.com. Pilot Operated 2 Port Solenoid Valve For Dry Air Series VQ20/30 How to Order Valves (Single unit) VQ A C6 2 1 1 1 G Series/ Orifice size Option Symbol 2 3 Nil: None Series VQ20 VQ30 F: With bracket Valve type (A) 2 N.C. 1 L: Type L (VQ20 only) 1 (P) Body type Note) If ordering both options
SZ 75 VP4 39.5 S0700 VQ VQ4 Individual SUP spacer VVQZ1000-P-5-M5 (-Q) (for VQZ1000) VVQZ2000-P-5-01 (-Q) (for VQZ2000) VVQZ3000-P-5-02 (-Q) (for VQZ3000) VQ5 + Rc1/8:VQZ2000 M5:VQZ1000 VQC Rc1/4:VQZ3000 VQZ D Supply port can be installed individually by mounting an individual supply spacer onto the manifold block.
How to Find the Flow Rate (at air temperature of 20 ) Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) S: Effective sectional area (mm 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow