Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.
For details about certified products conforming to international standards, visit us at www.smcworld.com. Pilot Operated 2 Port Solenoid Valve For Dry Air Series VQ20/30 How to Order Valves (Single unit) VQ A C6 2 1 1 1 G Series/ Orifice size Option Symbol 2 3 Nil: None Series VQ20 VQ30 F: With bracket Valve type (A) 2 N.C. 1 L: Type L (VQ20 only) 1 (P) Body type Note) If ordering both options
VQZ100 VQZ100-S-01(R) (-Q)Note) Note) For AC voltage valves there is no S option. It is already built-in to the rectifier circuit. 01 02 VQZ200 VQZ200-S(-Q) Caution 02 03 VQZ300 VQZ300-S(-Q) Thread type Note) R indicates external pilot type. Except VQZ100, external pilot type and internal pilot type are common.
How to Find the Flow Rate (at air temperature of 20 ) Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) S: Effective sectional area (mm 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow