Special version of the VP series valve that conforms to ISO13849-1 safety standard, categories 3 and 4. These are a dual residual pressure release valve with detection of main valve position.
Valve with Detection of Main Valve Position VP500/700-X536, X538, X555 How to Order Residual pressure release valve VP 2 5 4 5 Z R D 1 03 M X536 VP 4 1 X538 5 4 R 5 D Z 03 M A Dual residual pressure release valve Dual residual pressure release X555 VP 4 1 5 4 5 D Z 03 M valve with soft start-up function Throttle Thread Series Nil Variable throttle 10 1 xed orice 15 1.5 xed orice 20* 2 xed
Similar items in stock.
Dimensions Dual Residual Pressure Release Valve with Soft Start-up Function (-X555) VP744(R)-5 D YZ1-04 -X555 VP744(R)-5 D YZ1-04 -M -X555 1/2" [2(A) port] 40 Safety limit switch Made by OMRON 18 Safety limit switch (made by OMRON) Part number: D4N-2B31 (G1/2) : D4N-9B31 (M12 connector) A Port size: 1/8" (Without check valve) Applicable tube O.D.: 6, 1/4" (With check valve) (External pilot
254.2 AW30-03G-A Y300T-A E300-03-A VP744-5DZ1-04-X538 34.4 75.2 118.7 262.7 AW40-04G-A Y400T-A E400-04-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 AW40-04G-A Y400T-A E400-04-A 17 VP500/700-X536, X538, X555 Specific Product Precautions Be sure to read this before handling.