Special version of the VP series valve that conforms to ISO13849-1 safety standard, categories 1 and 2. This is a single residual pressure release valve with detection of main valve position.
Valve with Detection of Main Valve Position VP500/700-X536, X538, X555 How to Order Residual pressure release valve VP 2 5 4 5 Z R D 1 03 M X536 VP 4 1 X538 5 4 R 5 D Z 03 M A Dual residual pressure release valve Dual residual pressure release X555 VP 4 1 5 4 5 D Z 03 M valve with soft start-up function Throttle Thread Series Nil Variable throttle 10 1 xed orice 15 1.5 xed orice 20* 2 xed
Similar items in stock.
254.2 AW30-03G-A Y300T-A E300-03-A VP744-5DZ1-04-X538 34.4 75.2 118.7 262.7 AW40-04G-A Y400T-A E400-04-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 AW40-04G-A Y400T-A E400-04-A 17 VP500/700-X536, X538, X555 Specific Product Precautions Be sure to read this before handling.
254.2 AW30-03G-A Y300T-A E300-03-A VP744-5DZ1-04-X538 34.4 75.2 118.7 262.7 AW40-04G-A Y400T-A E400-04-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 AW40-04G-A Y400T-A E400-04-A 17 VP500/700-X536, X538, X555 Specific Product Precautions Be sure to read this before handling.
Model: 5 (VP500), Body: 42 (Body Ported), Pilot: R (External Pilot), Valve Electrical Entry: D (DIN Terminal w/Connector, w/Pitch 9.4mm Standard), Port: 03 (3/8, VP500), Thread: Rc, Bracket: None, Switch Electrical Entry: G 1/2, OMRON, Check Valve, External Pilot Only: None