Special version of the VP series valve that conforms to ISO13849-1 safety standard, categories 1 and 2. This is a single residual pressure release valve with detection of main valve position.
Valve with Detection of Main Valve Position VP500/700-X536, X538, X555 How to Order Residual pressure release valve VP 2 5 4 5 Z R D 1 03 M X536 VP 4 1 X538 5 4 R 5 D Z 03 M A Dual residual pressure release valve Dual residual pressure release X555 VP 4 1 5 4 5 D Z 03 M valve with soft start-up function Throttle Thread Series Nil Variable throttle 10 1 xed orice 15 1.5 xed orice 20* 2 xed
Dimensions Residual Pressure Release Valve (-X536) VP542(R)-5 D YZ1-03 -X536 VP542(R)-5 D YZ1-03 -M -X536 3/8" [2(A) port] Port size: 1/8" (Without check valve) Applicable tube O.D.: 6, 1/4" (With check valve) (External pilot port) 31 2 x 4.2 (For mounting) Safety limit switch Made by OMRON 3.5 7 4.5 26 22.1 118.9 (Max. 10) 201.8 Applicable cable O.D. 3.5 to 7 Safety limit switch (made by
Valve with Detection of Main Valve Position VP500/700-X536, X538, X555 How to Order Residual pressure release valve VP X536 2 5 4 5 Z R D 1 03 M X538 VP 4 1 5 4 R 5 D Z 03 M A Dual residual pressure release valve Dual residual pressure release X555 VP 4 1 5 4 5 D Z 03 M valve with soft start-up function Throttle Thread Series Nil Variable throttle 10 1 fixed orifice 15 1.5 fixed orifice 20
Note 4) -01, -02, -03,-06 at the end of the part number indicates the port size. (01: 1/8, 02: 1/4, 03: 3/8, 04: 1/2, 06: 3/4) Note 5) The pressure gauge for AW1000-M5G-1 will be G27-10-R1 for 1.0MPa.