The VNC series is for controlling the cutting oils and coolants used in machine tools. It is available as both Normally Closed or Normally Open type.
push type A (projecting) N.C. 0.5 MPa N.O. 1 MPa N.C. 1 MPa 4 1 6A 8A 10A 10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz Valve size 1 7 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC. 20 (14) 3 25 (16) 4 1 1 1 4 32 (22) 5 1 B 1 4 Flange 32F Nil: Non-locking push type 40A
VNB1 -6A, 8A, 10A VNB2 -10A, 15A VNB3 -20A VNB4 -25A VNB5 -32A, 32F VNB5 4 -32A, 32F VNB6 -40A, 40F VNB6 4 -40A, -40F VNB7 -50A, 50F VNB7 4 -50A, 50F No.
Doc. no.VN-OMM0001-C Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions -2,3 Precautions on Design -4 Selection -4 Mounting -4 Piping -5 Operating Environment -5 Maintenance -5 Precautions -5 How to use DIN connector -6 Indicator Light/Surge Voltage Suppressor -6 Electorical Connections -6 Specific Product Precautions -7,8 Troubleshooting
Similar items in stock.
This is a legacy product, and replaced byVNA611A-40A-5DZ, VALVE, SOL, VALVE, VNA/B/C/D 2-WAY MEDIA VALVE, 1A, VNA/B/C/D, 5.52447 lb