VFA 5 Port air operated valves are available in body ported or base mounted styles. The VFA uses the same manifolds as VF Series.
5 Port Air Operated Valve VFA1000/3000/5000 Series Single Unit Body Ported RoHS How to Order Valve VFA 3 1 3 0 01 Body ported Pilot port direction Series 1 3 5 VFA1000 VFA3000 VFA5000 Nil: Upward P: Lateral Pilot port Type of actuation 1 2 3 4 5 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center Pilot port Only 1 and 2 are available
Exhaust center: A, B R1, R2, Pressure center P A, B 3 position closed center 3 position exhaust center Specifications 2 position double 2 position single Fluid Air 0.15 to 0.9 0.1 to 0.9 Operating pressure range (MPa) 3 position pressure center 3 position 0.15 to 0.9 Pilot pressure range (MPa) 2 position double 2 position single (0.4 X P+0.1) to 0.9 P: Operating pressure 0.1 to 0.9 3 position
Body type Body type Plug-in type Non plug-in type VVFS2000-20A-1 VVFS2000-20A-2 Part no. 1 8 Plug-in type Non plug-in type VVFS2000-P-01-1 VVFS2000-P-01-2 VVFS2000-P-02-1 VVFS2000-P-02-2 Rc Body type Plug-in type Non plug-in type VVFS2000-10A Part no. Part no.
Set pressure with a flat head screw driver. 42 Base Mounted Type Series VQ5000 Plug-in Unit Metal seal type Rubber seal type (A) 4 (B) 2 VQ5101 (A) 4 (B) 2 VQ5100 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5201 (A) 4 (B) 2 (A) 4 (B) 2 VQ5200 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5301 VQ5300 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5401 VQ5400 (A) 4 (B) 2 (A) 4