Series VCH41/42 is a 2 port pilot operated solenoid valve for high pressure application. Designed for use with air or inert gas, the VCH valve can operate up to a maximum pressure of 5.0 MPa. With reduction in the overall volume of the pilot chamber, the VCH's responsiveness can now be measured in just milliseconds. Non-collision armature construction, rubber buffers and a urethane diaphragm
5 o y i q t u !0 !1 e w r !3 !8 !7 @3 @0 !9 @4 @1 @2 @6 @5 @7 @8 LVM No.
Valve Type: 2 (N.O.), Voltage: 5 (24 VDC), Electrical Entry: DL (DIN Connector with light), Port Size: 06 (3/4)
Valve Type: N.O., Voltage: 24 VDC, Electrical Entry: DIN Connector with light, Port Size: 3/4, CE Compliant Marking: -
In the case of liquid: P Q = 1.9 x 106Av (9) G Q : Flow rate [l/min] Av : Flow coefficient [m2] P : Pressure difference [MPa] G : Relative density [water = 1] In the case of saturated aqueous vapor: Q = 8.3 x 106Av P(P2 + 0.1) (10) Q : Flow rate [m3/s] Av : Flow coefficient [m2] P : Pressure difference [Pa] P1 : Relative density [MPa]: P = P1 P2 P2 : Relative density [MPa] Front matter 4