The RQ series air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end.
) With auto switch: 10C to 60C (No freezing) Female thread Ambient and fluid temperature Rod end thread Stroke length tolerance Mounting Piston speed +1.0 0 Through-hole 50 to 500 mm/s Standard Stroke Standard stroke (mm) Bore size (mm) 20, 25 32, 40 50, 63 80, 100 15, 20, 25, 30, 40, 50 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 40, 50, 75, 100 Made to Order (For details, refer to pages
) With auto switch: 10C to 60C (No freezing) Female thread Ambient and fluid temperature Rod end thread Stroke length tolerance Mounting Piston speed +1.0 0 Through-hole 50 to 500 mm/s Standard Stroke Standard stroke (mm) Bore size (mm) 20, 25 32, 40 50, 63 80, 100 15, 20, 25, 30, 40, 50 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 40, 50, 75, 100 Made to Order (For details, refer to pages
Compact Cylinder with Air Cushion Construction Series RQ Replacement Procedure is 20, 25, 32, 40 50, 63, 80, 100 P.290 20 to 40 50 to 100 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !7 !8 !6 !7 !8 !6 A part A part !4 !3 !2 !
Magnet: None, Mounting: B [Through Hole (Standard)], Bore Size: 100mm, Port Thread: TN (NPT), Stroke: 40mm, Body Option: M (Rod End Male Thread)
Magnet: None, Mounting: B [Through Hole (Standard)], Bore Size: 100mm, Port Thread: TN (NPT), Stroke: 100mm, Body Option: M (Rod End Male Thread)
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Support bracket
The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion
The RQ series new air cushion construction allows this series to retain the merits of a compact cylinder. The unique air cushion construction eliminates the cushion ring used in conventional type air cushions, which reduces the overall length of the cylinder. The RQ series meets the demands for reduced shock, noise reduction and improved repeatability at the stroke end. Unique air cushion
Magnet: None, Mounting: Basic, Bore Size: 160mm, Thread: NPT, Stroke 1: 50mm, Rod Boot 1: None, Stroke Adjustment: None, +: +, Stroke 2: 50mm, Rod Boot 2: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod Type
Magnet: Built-in Magnet, Mounting: Head Flange, Bore Size: 125mm, Thread: NPT, Stroke 1: 50mm, Rod Boot 1: None, Stroke Adjustment: None, +: +, Stroke 2: 50mm, Rod Boot 2: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Single Rod Type
Magnet: Built-in Magnet, Mounting: Basic, Bore Size: 125mm, Thread: Rc, Stroke 1: 50mm, Rod Boot 1: None, Stroke Adjustment: None, +: +, Stroke 2: 50mm, Rod Boot 2: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod Type