PFCA7 is a flow controller for clean, dry compressed air, N2, Ar, or CO2.  The design integrates a flow sensor, valve, and control mechanism for automatic adjustment in response to an analog voltage or current signal.  Control is linear and stepless within the rated flow ranges offered.  Features include 10 port options, a dot-matrix LCD color display that rotates 90°, raised

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: 01 (Rc1/8), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side))

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C8 (8mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only)

Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: Y (None

Stations: 8 Stations, Cylinder Port Size: N1 (1/8" One-touch Fitting), P, R Port Size: N7 (1/4" One-touch Fitting), Option 1: D (DIN Rail)

Stations: 12 Stations, Cylinder Port Size: N1 (1/8" One-touch Fitting), P, R Port Size: N7 (1/4" One-touch Fitting), Kit: SD0 (w/o SI Unit)

Stations: 8 Stations, Cylinder Port Size: N1 (1/8" One-touch Fitting), P, R Port Size: N7 (1/4" One-touch Fitting), Kit: SD0 (w/o SI Unit)

Stations: 12 Stations, Cylinder Port Size: N1 (One-touch Fitting for 1/8"), P, R Port Size: N7 (One-touch Fitting for 1/4"), Kit: SD0 (w/o Serial Unit)

Stations: 10 Stations, Cylinder Port Size: N1 (One-touch Fitting for 1/8"), P, R Port Size: N7 (One-touch Fitting for 1/4"), Kit: SD0 (w/o Serial Unit)

Stations: 15 Stations, Cylinder Port Size: N1 (One-touch Fitting for 1/8"), P, R Port Size: N7 (One-touch Fitting for 1/4"), Kit: SD0 (w/o Serial Unit)

Stations: 4 Stations, Cylinder Port Size: N1 (One-touch Fitting for 1/8"), P, R Port Size: N7 (One-touch Fitting for 1/4"), Kit: SD0 (w/o Serial Unit)