PFCA7 is a flow controller for clean, dry compressed air, N2, Ar, or CO2. The design integrates a flow sensor, valve, and control mechanism for automatic adjustment in response to an analog voltage or current signal. Control is linear and stepless within the rated flow ranges offered. Features include 10 port options, a dot-matrix LCD color display that rotates 90°, raised
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C8 (8mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: Y (None
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core))
FLOW CONTROLLER FOR AIR, AIR FLOW CONTROLLER, Q46, 180.00000 lb
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread: R, Port Size: 01 (1/8), Applicable Tubing: 01 (ø1/8"), Seal Method: None
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Thread: R, Port Size: 01 (1/8), Applicable Tubing: 01 (ø1/8"), Seal Method: None
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread: R, Port Size: 01 (1/8), Applicable Tubing: 01 (ø1/8"), Seal Method: None
Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8)
Display Pressure: 4 (0.4MPa), Connection Thread: 01 (R 1/8)
Display Pressure: 2 (0.2MPa), Connection Thread: 01 (R 1/8)
Display Pressure: 6 (0.6MPa), Connection Thread: 01 (R 1/8)
Display Pressure: 7 (0.7MPa), Connection Thread: 01 (R 1/8)