PFCA7 is a flow controller for clean, dry compressed air, N2, Ar, or CO2. The design integrates a flow sensor, valve, and control mechanism for automatic adjustment in response to an analog voltage or current signal. Control is linear and stepless within the rated flow ranges offered. Features include 10 port options, a dot-matrix LCD color display that rotates 90°, raised
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only), Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with Operation
AIR FLOW CONTROLLER. FLOW CONTROLLER FOR AIR. 305.00000 lb. Q46.
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: N (Without Lead Wire w/Function), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: 01 (Rc1/8), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V)
AIR FLOW CONTROLLER. FLOW CONTROLLER FOR AIR. 0.48500 lb. Q46.
AIR FLOW CONTROLLER. FLOW CONTROLLER FOR AIR. 0.48500 lb. Q46.
Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: M (SI units only)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)
Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: M (SI Unit Only)
Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)