PF3W7-X365 is an application specific version of the standard PF3W7 with SUS316 stainless steel compression fittings in place of the threaded pipe adapters. Further refinements include EPDM seals, as well as double O-rings when the optional flow adjustment valve is selected. These upgrades allow for the measurement of the flow of fluorinated liquids such as Fluorinert™ or GALDEN
Output specification/Temperature sensor Integrated display R Symbol OUT1 OUT2 Temperature sensor Flow rate Flow rate Temperature NPN PNP Analog 1 to 5 V Analog 4 to 20 mA Analog 1 to 5 V Analog 4 to 20 mA A B C D E F G H AT BT CT DT ET FT NPN PNP Analog 1 to 5 V Analog 4 to 20 mA Analog 1 to 5 V Analog 4 to 20 mA External input Note 1) NPN PNP NPN NPN PNP PNP NPN PNP NPN PNP NPN NPN PNP PNP
C 4/16/40 100 250 C C D A B Voltage output 1.5 V 6 mA 1.4 V 1.8 V 1 V 5 V 0.6 V 1 V Voltage output Current output 5.6 mA 7.2 mA 4 mA 20 mA 2.4 mA 4 mA Current output Minimum Model Rated flow [L/min] C D Maximum B PF3W B 5 V 5.4 V Voltage output PF3W704/504 PF3W720/520 PF3W740/540 PF3W711/511 PF3W721/521 0.5 2 5 10 50 4 A 20 mA 21.6 mA Current output A 16 40 0 Flow rate Minimum Maximum rated
1 V 1.8 V 5 V Current output 4 mA 7.2 mA 20 mA (PF3W721-U30) A B C Voltage output 1 V 1.48 V 5 V Current output 4 mA 5.92 mA 20 mA Rated flow [L/min] Sensor model Minimum Maximum PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721-12/14 50 250 PF3W721-U30 30 250 Analogue output (Fluid temperature) A B C D Voltage output 0.6 V 1 V 5 V 5.4 V Current output 2.4 mA 4 mA 20 mA 21.6