Series PF3W5-Z digital flow sensor constantly monitors water or coolant flow. All "Z" models have redesigned piping adapters, imparting a significant weight reduction and slimmer profile, depending on flow range. PF3W5 is the remote version without a display. The lower profile body can be deployed in tighter locations that may be out of an operator's view. Two LEDs are visible on the control
3-color display Digital Flow Switch for Water Series PF3W RoHS How to Order Remote sensor unit Output specification/Temperature sensor Remote sensor unit/Unit printed on label Symbol Temperature oC Symbol OUT1 Flow rate OUT2 Temperature Temperature sensor 1 2 1T Instantaneous flow rate L/min L/min (gal/min) For how to order of remote monitor unit, refer to page 18.
Pin name 1 2 3 4 DC (+) OUT2 DC () OUT1 1 3 2 x Piping port Z U T S 4 x WX G 2 4 (35.5) 42 H For PF3W721 OUT IN AA G 4 x P K L 2 x Piping port G N DD PF3W504/520/540/511/521 Remote sensor unit Y A E J F 30 W B V 2 x Piping port Z S T U 4 x WX G H 42 (35.5) For PF3W521 IN OUT AA G 4 x P K L 2 x Piping port G N (mm) Bracket dimensions Model Port size A AA B D DD E F G H J K L N P (Rc, NPT,
K S Model PF3W504S--T 115 50 81.2 69.5 67.5 PF3W520S--T 123 54 85.2 73.5 71.5 PF3W540S--T 153 71 105.5 90 89 -45No.PF-OMN0010-J PF3W511-U25/PF3W521-U30 (Vinyl chloride piping) Piping port A B D E F J K L N P Q 25 A 154 46 77 57.6 23 77 63 28 18 3.5 depth 14 32 32 A 146 56 91 71.6 28.5 73 60.5 25 27.5 3.5 depth 14 38 Bracket dimensions Piping port S T U V W Y Z 25 A 59 36 48 58 70 7 2 -46No.PF-OMN0010