Series PF3W5-Z digital flow sensor constantly monitors water or coolant flow. All "Z" models have redesigned piping adapters, imparting a significant weight reduction and slimmer profile, depending on flow range. PF3W5 is the remote version without a display. The lower profile body can be deployed in tighter locations that may be out of an operator's view. Two LEDs are visible on the control
Note) G, F, J: Made to Order Reference: 1 [L/min] 0.2642 [gal/min] 1 [gal/min] 3.785 [L/min] oF = 9/5oC + 32 Note 2) Note 2) Note 2) Note 2) Options/Part No. Lead wire Nil N When optional parts are required separately, use the following part numbers to place an order.
Pin name 1 2 3 4 DC (+) OUT2 DC () OUT1 1 3 2 x Piping port Z U T S 4 x WX G 2 4 (35.5) 42 H For PF3W721 OUT IN AA G 4 x P K L 2 x Piping port G N DD PF3W504/520/540/511/521 Remote sensor unit Y A E J F 30 W B V 2 x Piping port Z S T U 4 x WX G H 42 (35.5) For PF3W521 IN OUT AA G 4 x P K L 2 x Piping port G N (mm) Bracket dimensions Model Port size A AA B D DD E F G H J K L N P (Rc, NPT,
30 18 13.6 2.7 depth 12 PF3W540 1/2, 3/4 98 71 38 53.6 48.6 19.2 32 28 49 35 28 16.8 2.7 depth 12 PF3W511 3/4, 1 124 92 46 62.6 57.6 23 41 42 63 48 28 18 3.5 depth 14 Symbol Bracket dimensions Model S T U V W WX Y Z PF3W504 24 22 32 40 50 4.5 5 1.5 PF3W520 28 22 32 40 50 4.5 5 1.5 PF3W540 34 30 42 48 58 4.5 5 1.5 PF3W511 44 36 48 58 70 5.5 7 2 -41No.PF-OMN0010-J PF3W521 Basic type Symbol
Similar items in stock.