SMC Corporation of America
Elite Part Number Search
Search Results "PF3W511-N10-2"
type, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, HB, IFW/PFW 1 INCH NPT VERSION, 1.98416 lb, ModelApplicable fluidDetection methodRated flow rangeFluid temperatureAccuracyRepeatabilityTemperature characteristicsOperating pressure range Note 2)Proof pressure Note 2)Pressure lossAnalog outputIndicator lightPower supply voltageCurrent consumptionEnvironmentStandards

PF3W is a digital flow sensor that constantly monitors water or coolant flow.  PF3W refreshes the design and operating performance of the legacy PF2W model.  This is the remote version of PF3W7, with a display.  One or two analog outputs are available, depending on whether the optional temperature sensor is selected.  Additional options include a mounting bracket, flow adjustment valve and

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Note) G, F, J: Made to Order Reference: 1 [L/min] 0.2642 [gal/min] 1 [gal/min] 3.785 [L/min] oF = 9/5oC + 32 Note 2) Note 2) Note 2) Note 2) Options/Part No. Lead wire Nil N When optional parts are required separately, use the following part numbers to place an order.

Pin name 1 2 3 4 DC (+) OUT2 DC () OUT1 1 3 OUT IN 2 4 4 x 3.5 depth 14 28 63 32 18 62.6 PF3W511-U25 Remote sensor unit IN OUT ZS-40-A Lead wire with M8 connector 2 (White) (Black) 4 Lead Wire Specifications 4 Nominal cross section O.D. Material O.D. Color Material 10 AWG23 Conductor (Blue) 3 1 (Brown) Approx. 0.7 mm (15) M8 Heat resistant PVC (45) Approx. 1.1 mm Insulator Pin no.

(with 500VDC) between the terminals and housing Standards and regulations CE marking, UL(CSA), RoHS PPS, SUS304, FKM, SCS13 PPS, SUS304, FKM Wetted materials Non-grease type Piping port size 5 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 11/4, 11/2 -28No.PF-OMN0010-J Model PF3W504 PF3W520 PF3W540 PF3W511 PF3W521 Flow sensor only 195 g 245 g 395 g 705 g 875 g With temperature sensor 270 g 320 g 515 g 840

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 10 (1), Output Specification/Temperature Sensor: 2 (Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration Certificate:

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal Material

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal