PF3A8*H digital flow sensors with modular connection provides simple integration with SMC's AC30 and AC40 series air preparation units. The flow sensor provides instantaneous flow data as well as cumulative air consumption values. In addition to flow data, the PF3A8*H models incorporate pressure and temperature sensing. These models include IO-Link and digital outputs with
Models PF3A801H PF3A802H Maximum moment (M): Nm 16 19.5 Max. moment (M) = Length (L) x Load (F) -21No.PF-OMY0005-A Wiring Connection Connections should only be made with the power supply turned off. Use a separate route for the product wiring and any power or high voltage wiring.
Similar items in stock.
For more detailed settings, set each function in the function selection mode. 2 OUT2 Models PF3A801H PF3A802H Output mode Configurable items Sub display (left) Snap shot function 3 DC(-) Lead wire with M12 connector 19.5 Max. moment (M) = Length (L) x Load (F) Maximum moment (M): Nm 16 Hysteresis OUT set value H_1, H_2 P_1 (n_1), P_2 (n_2) 4 OUT2 (C/Q) Hysteresis mode To obtain the operation
Moment (M) Nm 14.5 16 19.5 28 Max. Moment (M) = Length (L) x Load (F) If a commercially available switching power supply is used, be sure to connect the frame ground (FG) terminal to ground. Do not drop, hit or apply excessive shock to the product. Otherwise damage to the internal components may result, causing malfunction.
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)]