Series PF3A digital flow sensor provides continuous quantitative values as well as switched digital outputs when set flow levels are measured. When paired with an IO-Link master, measured values, settings, and device information can be accessed at an HMI screen or fieldbus networked monitoring device. 32-bit of process data include 16 bits for the measured value, 2 output bits for set points
Direct parameters page 1 DPP1 address Access Parameter name Initial value (dec) Content 0x07 R Vendor ID 0x0083(131) "SMC Corporation" 0x08 PF3A703H-xx-Lx-xxx PF3A703H-xx-L3x-xxx PF3A703H-xx-L4x-xxx PF3A706H-xx-Lx-xxx PF3A706H-xx-L3x-xxx PF3A706H-xx-L4x-xxx PF3A712H-xx-Lx-xxx PF3A712H-xx-L3x-xxx PF3A712H-xx-L4x-xxx 0X0190(400) 0X0191(401) 0X0192(402) 0X0193(403) 0X0194(404) 0X0195(405) 0X0196
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)
Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: Units Selection Function, Calibration Certificate: Made to Order