SMC Corporation of America
Elite Part Number Search
Search Results "PF3A712H-N20-L"

Series PF3A digital flow sensor provides continuous quantitative values as well as switched digital outputs when set flow levels are measured.  When paired with an IO-Link master, measured values, settings, and device information can be accessed at an HMI screen or fieldbus networked monitoring device.  32-bit of process data include 16 bits for the measured value, 2 output bits for set points

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: Units Selection Function, Calibration Certificate: A (Made to Order)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)

Rated Flow Range: 120 to 12000 l/min, Thread Type: NPT, Port Size: 2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: Units Selection Function, Calibration Certificate: Made to Order