Series PF3A digital flow sensor provides continuous quantitative values as well as switched digital outputs when set flow levels are measured. When paired with an IO-Link master, measured values, settings, and device information can be accessed at an HMI screen or fieldbus networked monitoring device. 32-bit of process data include 16 bits for the measured value, 2 output bits for set points
(reed or solid state input) for 30 ms or longer -22No.PF-OMX0002-B Used as IO-Link device PF3A7##H-##-L#-## PF3A7##H-##-L3/L4#-## : Numbers in the figures show the connector pin layout. -23No.PF-OMX0002-B Example of wiring for accumulated pulse output NPN output type PF3A7##H-##-L/L3/L4#-## PNP output type PF3A7##H-##-L/L3/L4#-## -24No.PF-OMX0002-B Outline of Settings [Measurement mode] Power
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: NPT, Port Size: 1 1/2, Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -
Digital Flow Switch, SENSOR, DIGITAL AIR FLOW, O24, 1.19000 lb
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 999 lb
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: Rc, Port Size: 14 (1 1/2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 60 to 6000 l/min, Thread Type: Rc, Port Size: 1 1/2, Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 60 to 6000 l/min, Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 1 1/2, Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: -, Unit Specification: -, Calibration Certificate: -
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)