PF3A7*H digital flow sensors with modular connection provides simple integration with SMC's AC30 and AC40 series air preparation units. The flow sensor provides instantaneous flow data as well as cumulative air consumption values. The -L models include IO-Link and digital outputs with optional analog outputs.
Direct parameters page 1 DPP1 address Access Parameter name Initial value (dec) Content 0x07 R Vendor ID 0x0083(131) "SMC Corporation" 0x08 PF3A701H-xx-Lx-xxx PF3A701H-xx-L3x-xxx PF3A701H-xx-L4x-xxx PF3A702H-xx-Lx-xxx PF3A702H-xx-L3x-xxx PF3A702H-xx-L4x-xxx 0X018A(394) 0X018B(395) 0X018C(396) 0X018D(397) 0X018E(398) 0X018F(399) 0x09 R Device ID 0x0A 0x0B -39No.PF-OMX0007-A ISDU parameters
Before Use Digital Flow Switch PF3A701H/PF3A702H The following options are required for coupling with modular F, R, and L combinations. They are separately prepared by the user.
(Page 77) 8000 0x1F40 0 R 8010 0x1F4A 0 R Flow rate PD conversion equation: b F32 N 8020 0x1F54 0 R Flow peak value S16 N 0x0 to 0x1068 (0 to 4200) 8030 0x1F5E 0 R Flow bottom value S16 N 8060 0x1F7C 0 R Accumulated PD conversion equation: a F32 N Measurement related 8070 0x1F86 0 R Accumulated PD conversion equation: b F32 N Refer to "Inclination and intercept to the unit specification".
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)