PF3A7*H digital flow sensors with modular connection provides simple integration with SMC's AC30 and AC40 series air preparation units. The flow sensor provides instantaneous flow data as well as cumulative air consumption values. The -L models include IO-Link and digital outputs with optional analog outputs.
Models PF3A701H PF3A702H Maximum moment (M): Nm 16 19.5 Max. moment (M) = Length (L) x Load (F) -18No.PF-OMX0007-A Wiring Connection Connections should only be made with the power supply turned off. Use a separate route for the product wiring and any power or high voltage wiring.
Models PF3A801H PF3A802H Maximum moment (M): Nm 16 19.5 Max. moment (M) = Length (L) x Load (F) -21No.PF-OMY0005-A Wiring Connection Connections should only be made with the power supply turned off. Use a separate route for the product wiring and any power or high voltage wiring.
For more detailed settings, set each function in the function selection mode. 1 DC(+) Output mode Configurable items Sub display (left) Snap shot function Models PF3A701H PF3A702H 2 FUNC OUT set value P(n) 19.5 Max. moment (M) = Length (L) x Load (F) Maximum moment (M): Nm 16 Hysteresis mode Lead wire with M12 connector 3 DC(-) Hysteresis H To obtain the operation manual about this product
Rated Flow Range: 02 (20 to 2000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]