PF3A7*H digital flow sensors with modular connection provides simple integration with SMC's AC30 and AC40 series air preparation units. The flow sensor provides instantaneous flow data as well as cumulative air consumption values. The -L models include IO-Link and digital outputs with optional analog outputs.
Direct parameters page 1 DPP1 address Access Parameter name Initial value (dec) Content 0x07 R Vendor ID 0x0083(131) "SMC Corporation" 0x08 PF3A701H-xx-Lx-xxx PF3A701H-xx-L3x-xxx PF3A701H-xx-L4x-xxx PF3A702H-xx-Lx-xxx PF3A702H-xx-L3x-xxx PF3A702H-xx-L4x-xxx 0X018A(394) 0X018B(395) 0X018C(396) 0X018D(397) 0X018E(398) 0X018F(399) 0x09 R Device ID 0x0A 0x0B -39No.PF-OMX0007-A ISDU parameters
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)
SENSOR, DIGITAL AIR FLOW. DIGITAL FLOW SWITCH. 0.35000 lb. O24.
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
DIGITAL FLOW SWITCH, SENSOR, DIGITAL AIR FLOW, O24, 380 lb
DIGITAL FLOW SWITCH-MODULAR, SENSOR, DIGITAL AIR FLOW, O24, 0.44000 lb
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None]