PF3A7*H digital flow sensors with modular connection provides simple integration with SMC's AC30 and AC40 air preparation units. The flow sensor provides instantaneous flow data as well as cumulative air consumption values. These units are available with digital and analog outputs.
When 20 A or more current flows, it is possible that the accuracy is not satisfied in the area at 0.5 V or lower. 4: The minimum value of the rated flow range changes based on the setting of zero cut-off function. -54No.PF-OMX0007-A Pressure loss (reference value) PF3A701H (For 1000 L/min) PF3A702H (For 2000 L/min) -55No.PF-OMX0007-A Dimensions Symbol Models A B D E F PF3A701H 68.3 43 64.4
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: -, Unit Specification: -, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: R (Right to Left)
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: None, Certificate in both English and Japanese, Flow Direction: Right to Left
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: Yes, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: Yes, Flow Direction: -
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: Yes, Flow Direction: -
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)
Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: Q (Lead wire with M12-M12 connector, 3 m), Unit Specification: Units Selection Function, Calibration Certificate: A (Yes), Flow Direction: R (Right to Left)
Rated Flow Range: 10 to 1000 l/min, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: Lead wire with M12-M12 connector, 3 m, Unit Specification: Units Selection Function, Calibration Certificate: Yes, Flow Direction: Right to Left
DIGITAL FLOW SWITCH, DIGITAL FLOW SWITCH, MODULAR, P65, 445.00000 lb