PF2W is a digital flow sensor for water or coolant. This is a legacy sensor, refreshed in 2009 as PF3W. This is the remote version of PF2W7, with a display. The mounting bracket is integrated into the body, while the M12 lead wire is optional. PF2W5 can be paired with a PF2W200 or PF2W300 remote monitor to display instantaneous or accumulated flow values. An optional analog output is also
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 23 Digital Flow Switch Series PF2W For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples to are the terminal numbers.
Nominal thread size Required torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm Model Width across flats of attachment PF2W504 34 mm PF2W520 PF2W540 PF2W511 45 mm PF2W504T 34 mm PF2W520T PF2W540T -16No.PF-OMO0014-D Wiring Connections should only be made with the power supply turned off.
Your search for PFW returned 30 result(s)
Product Information » New Products Search Results
Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: N (w/o Lead Wire)
Flow Range: 5~40 l/min, Thread: Rc, Port Size: 1/2, Wiring Specification: w/o Lead Wire, Output Specification: -
Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 5~40 l/min, Thread: Rc, Port Size: 1/2, Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (1~5V)
This is a legacy product, and replaced byVBA40A-04N
Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: NPN Open Collector 2 Outputs, Unit: -
Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: PNP Open Collector 2 Outputs, Unit: -
Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 0 (NPN Open Collector 2 Outputs)
Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 1 (PNP Open Collector 2 Outputs)
Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 06 (3/4), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 06 (3/4), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))