PF2W is a digital flow sensor for water or coolant. This is a legacy sensor, refreshed in 2009 as PF3W. This is the remote version of PF2W7, with a display. The mounting bracket is integrated into the body, while the M12 lead wire is optional. PF2W5 can be paired with a PF2W200 or PF2W300 remote monitor to display instantaneous or accumulated flow values. An optional analog output is also
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 23 Digital Flow Switch Series PF2W For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples to are the terminal numbers.
PF2W504(T) 0.5 4 PF2W520(T) 2 16 PF2W540(T) 5 40 PF2W511 10 100 Measurable range of ethylene glycol aqueous solution (Reference value) : The product with operating fluid temperature specification [0 to 50 oC] is not suitable for fluids with a temperature greater than 50 oC. -24No.PF-OMO0014-D Dimensions (in mm) PF2W504/520 Output specifications A B C Output for PF2W3 48 mm 62 mm 94.3 mm Output
Your search for PFW returned 30 result(s)
Product Information » New Products Search Results
Flow Range: 04 (0.5~4 l/min), Thread: Rc, Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))
Flow Range: 04 (0.5~4 l/min), Thread: Rc, Port Size: 03 (3/8), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))
Flow Range: 0.5~4 l/min, Thread: Rc, Port Size: 3/8, Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 0.5~4 l/min, Thread: Rc, Port Size: 3/8, Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (4~20mA)
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated
Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: NPN Open Collector 2 Outputs, Unit: -
Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: PNP Open Collector 2 Outputs, Unit: -
Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 0 (NPN Open Collector 2 Outputs)
Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 1 (PNP Open Collector 2 Outputs)
This is a legacy product, and replaced byVEX1300-03N
Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit