The MGJ is a miniature sized version of the MGP standard guided actuator designed for small load applications that require high accuracy. Its integrated guide rods provides a non-rotating accuracy of +/-0.1°. It is targeted for the electronic equipment and instrumentation industries and not intended for use in stopper applications.
Load voltage Lead wire length (m) Applicable load Type Special function Electrical entry Indicator light Wiring (output) Direct mounting 0.5 (Nil) 3 (L) 5 (Z) DC 3-wire (NPN) F8N Solid state switch IC circuit Relay PLC 5 V 12 V Grommet (Perpendicular) 3-wire (PNP) Yes 24 V F8P F8B 2-wire 12 V Lead wire length symbols: 0.5 m . Nil (Example) F8N 3 m . L (Example) F8NL 5 m .
MGG Maximum tightening torque (Nm) Bolt Model MGC Top mounting Bottom mounting MGJ6 M3 x 0.5 1.2 0.3 MGF MGJ10 M4 x 0.7 2.7 0.7 MGZ Top mounting Bottom mounting MGT Others Caution 1. This product should not be used as a stopper. D-X Individual -X 261
If a load is mounted to the plate while the piston rod is extended, the guide will be twisted which may lead to malfunction. 8) Tighten the screw to the appropriate tightening torque when mounting a load. Model Bolt Appropriate tightening torque (Nm) MGJ6 M2.5X0.45 0.5 MGJ10 M3X0.5 1.0 Figure 3-2 7 9) Do not use this cylinder as a stopper. 3-7.