The MGG integrates a round body, end lock cylinder for its power source with external guide rods to isolate the load bearing from the movement of the actuator's rod and seals for a one piece unit. The end lock can be specified for either the head end (H) or rod end (R) of the stroke. The brake spring, end lock mechanism will engage when air pressure is lost for drop prevention applications
-500 Moving parts basic mass 1.61 Additional mass for stroke 0.203/50 st Stroke 500 st 1.61 + 0.203 x 500/50 = 3.64 kg With piping ports for grease, auto switch rail mounting style X772 358
100 Bore size (mm) Moving parts basic mass 0.69 1.14 1.61 3.09 5.23 8.29 13.09 18.58 Additional mass by each 50 mm of stroke 0.109 0.135 0.203 0.326 0.509 0.679 0.948 1.265 Calculating mass of moving parts (Example) MGGLB32-500-HN Moving parts basic mass . 1.61 Additional mass for stroke 0.203/50 st Stroke 500 st 1.61 + 0.203 x 500/50 = 3.64 kg Refer to pages 360 to 368 for the allowable