LFE is a digital flow sensor for water and non-corrosive conductive liquids. While the PF3W sensors detect flow using the Karman vortex principle, LFE applies Faraday's law of induction. There are no obstacles or moving parts in the flow path, leading to a smaller pressure loss which saves pumping energy. Detectable liquids have fewer viscosity restraints. Finally, the flow direction can
Similar items in stock.
Setting range: 1-8 CC-Link setting Occupied area Number of registrable Operation Number of Bit area Word area RWr/RWw Mode CC-Link Ver Extended cyclic occupied units RX/RY stations 1 15 1.10 x1 2 64/64 8/8 2 15 1.10 x1 4 128/128 16/16 3 15 2.00 x8 2 384/384 64/64 4 15 2.00 x8 4 896/896 128/128 5 31 2.00 x8 2 384/384 64/64 6 31 2.00 x8 4 896/896 128/128 7 63 2.00 x8 4 896/896 128/128 8 127
Symbol 1 Piping connection parts: Stainless steel 304 -X8 Specifications Model LFE1-X8 LFE2-X8 LFE3-X8 Fluid contact materials PPS, FKM, Stainless steel 304 Weight (Body)*1 Integrated display type Approx. 380 g Approx. 430 g Approx. 620 g Approx. 800 g Remote type sensor unit Approx. 375 g Approx. 425 g Approx. 615 g Approx. 795 g *1 When options are used, add the weight of the optional parts
Extended cyclic occupied units RX/RY stations 1 15 1.10 x1 2 64/64 8/8 2 15 1.10 x1 4 128/128 16/16 3 15 2.00 x8 2 384/384 64/64 4 15 2.00 x8 4 896/896 128/128 5 31 2.00 x8 2 384/384 64/64 6 31 2.00 x8 4 896/896 128/128 7 63 2.00 x8 4 896/896 128/128 8 127 2.00 x8 4 896/896 128/128 * The last register of the bit area (16 bits) cannot be used as it is allocated for the system area.