SUP=0.3MPa 80 SUP=0.2MPa 60 Note 2) 1 cycle discharge rate PA3000: Approx. 22ml PA5000: Approx. 100ml Selection procedure 1. First mark the intersection point for a discharge rate of 4l/min and a lifting range of 15m. 2. Find the pilot air pressure for the marked point.