The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The LEY rod electric actuator is suitable for push, pull, lift and press applications.  The motor orientation can be reverse mounted on top for compact length, or inline for compact height.  Several mounting options are available to accommodate a range of machine requirements.  This version includes a 24VDC motor with a battery-less absolute encoder.  This encoder allows the actuator to be

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Electric Actuator New New Rod Type Guide Rod Type Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Rod Type Series LEY Size: 16, 25, 32 Long stroke: Max.500 mm (LEY32) New Mounting variations N Direct mounting: 3 directions, Bracket mounting: 3 types N Auto switch can be mounted. N Speed control/Positioning: Max. 64 points N Either positioning or pushing control can be selected. Possible

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: C (w/Motor Cover)

Size: 40, Motor Mounting Position: In-line, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: -, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication Plug Connector: -

Size: 40, Motor Mounting Position: In-line, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 300mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: -, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication Plug Connector: -

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 400mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: None, Controller: CE1 (EtherCAT®), Mounting: 7 (Screw Mounting)

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R3 (3m), Controller: CM1 (CC-Link Ver. 1. 10), Mounting: 8 (DIN Rail), I/O Cable: w/o Cable

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: None, Controller: CE1 (EtherCAT®), Mounting: 7 (Screw Mounting)

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R3 (3m), Controller: CM1 (CC-Link Ver. 1. 10), Mounting: 8 (DIN Rail), I/O Cable: w/o

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: None, Controller: CE1 (EtherCAT®), Mounting: 8 (DIN Rail)

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R3 (3m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)

Size: 40, Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 350mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Protocol: L (IO-Link), Mounting: 8 (DIN Rail), Cable Connector: None, Actuator: LEY, Body Size: 40, Motor Mounting: D (In-line), Lead: A (16: 10mm; 25: 12mm; 12; 32/40: 16mm), Stroke: 30mm

Protocol: E (EtherCAT®), Mounting: 8 (DIN Rail), Cable Connector: None, Actuator: LEY, Body Size: 40, Motor Mounting: D (In-line), Lead: A (16: 10mm; 25: 12mm; 12; 32/40: 16mm), Stroke: 300mm

Protocol: 9 (EtherNet/IPâ„¢), Mounting: 7 (Screw Mounting), Cable Connector: None, Actuator: LEY, Body Size: 40, Motor Mounting: D (In-line), Lead: A (16: 10mm; 25: 12mm; 12; 32/40: 16mm), Stroke: 500mm