Electric Actuator/Rod Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) LEY16, 25, 32 Series LEY How to Order LEY 16 30 B 1 1 6N S q w e r t y u i o !0 !1 !2 !3 q Size r Lead [mm] y Motor option1 LEY16 10 5 2.5 16 25 32 LEY25 12 6 3 LEY32 16 8 4 Without option With motor cover With lock2 Symbol Nil C B A B C 1 When [With lock] is selected, [With motor cover] cannot be selected. 2 For 30
Duty ratio = A/B x 100 [%] 40 or less 100 50 70 12 70 20 1.3 36 85 15 0.8 Lead 2.5: LEY16C 31.5 [Set value of pushing force] is one of the step data input to the controller. [Continuous pushing time] is the time that the actuator can continuously keep pushing.
No.LEY*-OMZ0015 NN32598001 PRODUCT NAME Electric Actuator Rod Type AC Servo Motor MODEL / Series LEY Series Applicable models: LEY , LEYG LEYG Series Guide Rod type LEY Series Rod type #This manual describes the actuators operation in combination with the LECS / LECY series drivers. #Refer to the manual relevant to the controller being used for full operating instructions. Contents Safety
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for LEC: 1
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC:
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: Without
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller Mounting
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable,
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Size: 7 (ø50), Valve Type: 0 [NC (Operating Pressure 1MPa)], Body Material: Standard (Bronze Body), Thread: Rc(PT), Port Size: 50F (2B Flange)
Size: 7 (ø50), Valve Type: 2 [NO (Operating Pressure 1MPa)], Body Material: Standard (Bronze Body), Thread: Rc(PT), Port Size: 50F (2B Flange)
Size: 7 (ø50), Valve Type: 0 [NC (Operating Pressure 1MPa)], Body Material: Standard (Bronze Body), Thread: N (NPT), Port Size: 50F (2B Flange)
Size: 7 (ø50), Valve Type: 0 [NC (Operating Pressure 1MPa)], Body Material: S (Stainless Steel Body), Thread: Rc(PT), Port Size: 50F (2B Flange)
Size: 7 (ø50), Valve Type: 2 [NO (Operating Pressure 1MPa)], Body Material: S (Stainless Steel Body), Thread: Rc(PT), Port Size: 50F (2B Flange)