(Refer to page 4, DIN rail and DIN rail mounting adapter for details.) 1 3 5 1 m 20 mm 3 m 30 mm 5 m Actuator cable length Nil ControllerNote 1) Without cable Nil 1 3 5 Without controller 1 m N P With controller (NPN) 3 m With controller (PNP) 5 m System Construction Note 3) Separately sold products Note 2) QController type Note 1) Provided by customer Option Note 1) QCounter cable QMulti-counterNote
LAT3-10 LAT3F-10 LAT3-20 LAT3F-20 LAT3-30 LAT3F-30 5 10 20 30 Model Stroke [mm] Positioning repeatability [m] 90 5 90 5 90 Check the load mass and load factor. 3 From Fig. 2: = 0, find Wmax = 500 As W = 200 < Wmax = 500, the selected model can be used. Fig.2 Wmax Find the allowable load mass Wmax [g] from the graph.
[ m] Note 4) Note 5) 90 5 90 5 90 5 20 5 Measurement Accuracy [ m] Note 4) Note 5) 100 10 100 10 100 10 40 10 Maximum speed [mm/s] Note 6) 400 Operating temperature range [oC] 5 to 40 (No condensation) Operating humidity range [%] 35 to 85 (No condensation) Weight [g] Note 7) 130 190 250 360 Table weight [g] 50 70 90 110 Note 1) Continuous thrust can be generated and maintained continuously
Sensor Resolution: F (1.25 μm), Stroke: 10mm, Actuator Cable Length: 5m, Controller: AP (LATCA, PNP), I/O Cable Length: 5m, Controller Mounting: D (DIN Rail Mounting, DIN Rail not Included)