The JXC*1 is a single axis controller for LE's 24VDC step motors with absolute encoders, compatible with several fieldbus protocols including Ethernet/IP™ fieldbus. Actuator motors can be operated by calling a line of step data or by direct numerical instruction, each possible over the network. Futher fieldbus
Similar items in stock.
Movement Speed Position Acceleration Deceleration Area 1 Area 2 In pos force Force speed force 2 2 mode mm/s mm mm/s mm/s mm mm mm Value mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () (1)No.
From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm). Then, the actuator should move from the position where the pushing operation was completed (where INP turned ON) to a point 50 mm away at 50 mm/s. (Step Data No.2 is used for this operation).
Size: 32, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: C (w/Motor Cover)