The JXC51 and JXC61 are controllers for LE's 24VDC step motors with the batteryless absolute encoders. Enter up to 64 motion control step data with position, speed, accelertion, and pushing force so they can be called in any sequence by the PLC using the parallel I/O interface. Data entry requires laptop software or a teaching pendant. An Easy mode for data entry is available for quick start
Similar items in stock.
Move Speed Position Accel Decel PushingF TriggerLV PushingSp Moving F Area1 Area2 In posn mm/s mm mm/s2 mm/s2 mm/s mm mm mm 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 Caution Writing of the step data should be performed while the electric actuator is stopped. 39 - Details of step data
Example) Electric actuator number LEY25DEB-50-M1CD17T-X8 (1) (1) LEY25DEB-50 -5No.LEY*-OMZ0010 2Specific product precautions About precautions for installation of electric actuator, refer to [Specific precautions for Battery-less absolute encoder] that is described in the manual of used controller. Precautions for use 1. Please install the tube.
Protocol: E (EtherCAT®), Single Axis, STO Function: F (1 Axis, w/STO Sub-function), Mounting: 7 (Screw Mounting), Actuator: LEY, Body Size: 25, Motor Mounting: D (In-line), Lead: B (16: 5mm; 25: 6mm; 32, 40: 8mm), Stroke: 100mm
Protocol: L (IO-Link), Single Axis, STO Function: F (1 Axis, w/STO Sub-function), Mounting: 7 (Screw Mounting), Actuator: LEY, Body Size: 25, Motor Mounting: D (In-line), Lead: B (16: 5mm; 25: 6mm; 32, 40: 8mm), Stroke: 100mm