Series JMGP compact guided actuators are double acting, compact and lightweight. The JMGP is suitable for pushing, lifting or clamping applications.
Series Variations Model Bearing Bore size Stroke [mm] Cushion Piston speed Port size Mounting direction JMGP 12 (10 x 2) 10, 20, 30, 50, 100 M3 x 0.5 16 (12 x 2) 20 (16 x 2) 20, 30, 50, 100, 150 M5 x 0.8 25 (20 x 2) 50 to 300 mm/s Top 32 (25 x 2) Rubber bumper on both ends Slide bearing Bottom 40 (32 x 2) 1/8 (Rc, NPT, G) 50 (40 x 2) Rear 25, 50, 100, 150, 200 63 (45 x 2) 80 (56 x 2) 50 to
, Center trunnion Mounting Minimum Stroke for Auto Switch Mounting Standard Stroke Standard stroke (mm) Bore size (mm) Max. stroke Refer to page 28 for Minimum Stroke for Auto Switch Mounting. 32 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1900 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1900 25, 50,
[mm] (Reference value) 17 Weight 5.5 Most sensitive position [g] Auto switch model D-M9Nm-5 D-M9Pm-5 D-M9Bm-5 0.5 m (Nil) 7 6 Lead wire length 1 m (M) 13 11 3 m (L) 35 31 5 m (Z) 57 51 17-E683 D-M9m-5
[mm] (Reference value) 17 Weight 5.5 Most sensitive position [g] Auto switch model D-M9Nm-5 D-M9Pm-5 D-M9Bm-5 0.5 m (Nil) 7 6 Lead wire length 1 m (M) 13 11 3 m (L) 35 31 5 m (Z) 57 51 17-E683 D-M9m-5