The ITV-X399 standby electro-pneumatic regulator adds functionality to the standard ITV for use in the Air Management System. Like standard ITV, it allows the user to electronically control the pressure to the device. The capability of setting a standby pressure has been added, and the non-relieving design allows the system to decay to this pressure before the ITV maintains it at the set
Input/output characteristics chart VEA Communication Specifications (CC, DE, PR, RC) VY1 ITV00-CC CC-Link Ver 1.10 ITV00-DE DeviceNet Volume1 (Edition3.8), Volume3 (Edition1.5) ITV00-PR PROFIBUS DP DP-V0 ITV00-RC RS-232C Model VBA VBAT Protocol Version Note 1) 156 k/625 k 2.5 M/5 M/10 M bps 125 k/250 k/500 k bps 9.6 k/19.2 k/45.45 k 93.75 k/187.5 k/500 k 1.5 M/3 M/6 M/12 M bps 9.6 kbps Communication
Default: Gain 9 Bit Bit 3, 2, 1, 0 Value Bit 3 2 1 0 Setting 0 0 0 0 Gain 0 0 0 0 1 Gain 1 0 0 1 0 Gain 2 0 0 1 1 Gain 3 0 1 0 0 Gain 4 0 1 0 1 Gain 5 0 1 1 0 Gain 6 0 1 1 1 Gain 7 1 0 0 0 Gain 8 1 0 0 1 Gain 9 * 1 0 1 0 Gain A 1 0 1 1 Gain B 1 1 0 0 Gain C 1 1 0 1 Gain D 1 1 1 0 Gain E 1 1 1 1 Gain F * indicates the initial shipping value. 16 - Parameter index 0x43 Parameter name Sensitivity
Your search for ITV3000 returned 30 result(s)
There were no hits with the full part number, but there were 12 hits in the keyword search.
There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 40, Actuation: 2 (Normally Open), Pressure Display Unit: K (Units Selection Function)
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 40, Actuation: Normally Open, Pressure Display Unit: Units Selection Function
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 40, Actuation: 1 (Normally Closed), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 40, Actuation: Normally Closed, Pressure Display Unit: SI Units Only
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 40, Actuation: 2 (Normally Open), Pressure Display Unit: M (SI Units Only)
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 40, Actuation: Normally Open, Pressure Display Unit: SI Units Only
Body Size & Pressure Range: 3050 (AMS40A/60A), Input Signal: IL (IO-Link), Size: 60, Actuation: 1 (Normally Closed), Pressure Display Unit: K (Units Selection Function)
Body Size & Pressure Range: AMS40A/60A, Input Signal: IO-Link, Size: 60, Actuation: Normally Closed, Pressure Display Unit: Units Selection Function
The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available in MPa, kgf/cm², bar, PSI, and kPa units., Pressure range of 0.005 to 0.9MPa., Available port sizes 1/4 and 3/8., Mounting bracket option., Standby Electro-Pneumatic Regulator, REGULATOR, ELECTROPNEUMATIC, 853, 1.32000 lb