SMC Corporation of America
Elite Part Number Search
Search Results "ISE70G-N02-L2-A"
The ISE70/75(H) series pressure switches incorporate a large digital display to monitor both coolant and hydraulic fluids. 

The ISE70G pressure sensors provide continuous quantitative values, as well as switched digital outputs when pressure set points are met.  Compatible fluids include any non-corrosive liquid or gas.  6 pressure ranges are offered up to 50 MPa.  This sensor is also IO-Link compatible.  Sensor information, such as identity, functional state, cable connection, and current or switch values can be

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Description Nil None 1 ISO 1179-1 compliant A Bracket A (Interchangeable with ISE70) Output specification1 Symbol Description B Bracket B L2 IO-Link: Switch output 1 + Switch output 2 (Switch output: NPN or PNP switching type) Option 1 1 Refer to pages 7 and 10 for details.

A large bore cylinder or ejector consumes a large amount of air in operation and may experience a temporary drop in the primary pressure. This function prevents detection of such temporary drops in primary pressure as abnormal pressure.

Bracket A (Part No.: ZS-50-A) Bracket B (Part No.: ZS-50-B) -14No.PS-OMV0004-H Piping Piping specification: -02 and -N02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 8 to 12 Nm. Piping specification: -F02 After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting.