ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the ISE20, the ISE20C adds a 2nd switch output, as well as analog voltage or current output. The ISE20CH offers a 2 MPa pressure range. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange
1 Output 3-Screen Display High-Precision Digital Pressure Switch RoHS IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
02L: 60.5 N02L: 61 NPT1/4 2 M5 x 0.8 Thread depth 5 Piping port 02L: R1/4 N02L: NPT1/4 If there is a possibility that the atmospheric vent port of the switch will be exposed to water or dust, insert a tube into the atmospheric vent port and route the other end of the tube to a safe place away from water or dust. * For tubing, please use the SMC TU0425 (polyurethane, O.D. 4, I.D. 2.5) for
ZSE20CF : 50.0 kPa ISE20CH : 1.000 MPa ISE20C : 0.050 MPa ZSE20C : 5.1 kPa Hysteresis Appropriate setting of the hysteresis will prevent the switch output from chattering. ZSE20CF : 5.0 kPa ISE20CH : 0.100 MPa Delay time Delay time of the switch output can be selected. 1.5 ms or less Display color Selects the output according to the display color.
Similar items in stock.
Your search for ISE1-6 returned 30 result(s)
There were no hits with the full part number, but there were 67 hits in the keyword search.
There were no hits with the full part number, but there were 54 hits in the keyword search.
Product Information » New Products Search Results
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation Manual: -
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket:
Rated Pressure Range: -0.1 to 2 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket C, Operation
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)