ISE20C is a digital pressure sensor offering compatibility with both compressed air and non-corrosive liquids. Compared to the ISE20, the ISE20C adds a 2nd switch output, as well as analog voltage or current output. The ISE20CH offers a 2 MPa pressure range. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange
output P PNP open collector 1 output Symbol Description Nil Units selection function1 M SI unit only2 P Units selection function (Initial value psi)1 1 Under the New Measurement Act, switches with the units selection function are not permitted for use in Japan. 2 Fixed unit: kPa, MPa y Option 2 t Option 1 r Piping specification Symbol Description Nil None Symbol Description Symbol Description
Piping Applicable fluid Series Output type Enclosure Copy function 1/4 (R, NPT, G) (URJ*1/TSJ*2) M5 female thread 1/8 (R, NPT) ZSE20(F)/ ISE20 1 output IP40 U U p. 7 ZSE20A(F)/ ISE20A 2 outputs New New Analog output (Voltage/Current) IP40 U U Air p. 9 ZSE20B(F)/ ISE20B 2 outputs New New Analog output (Voltage/Current) IP65 U U U p. 11 ZSE20C(F)/ ISE20C(H) 2 outputs General fluids New
[F 0] Units selection function Page 32 Units specification Pressure range Default setting ISE20C(H) MPa "Nil" or M ZSE20C(F) kPa ISE20C(H) P psi ZSE20C(F) [F 1] Setting of OUT1 Page 33 Item Explanation Default setting Output mode Either hysteresis mode, window comparator mode, error output or output off can be selected.
Similar items in stock.
Your search for ISE1-6 returned 30 result(s)
There were no hits with the full part number, but there were 67 hits in the keyword search.
There were no hits with the full part number, but there were 54 hits in the keyword search.
Product Information » New Products Search Results
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: B2 [TSJ1/4 (Compression Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation Manual
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter), Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: B2 [TSJ1/4 (Compression Fitting)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: w/o Operation Manual
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: K (Operation
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: F (Panel Mount Adapter + Front
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration