SMC Corporation of America
Elite Part Number Search
Search Results "IC30-1"
power supply voltage and current signal indication: 1-digit LED indicator (red)LED lights for RUN, CH, SW (red and green)?
Series IC, controller for electro-pneumatic regulator converts digital input signal into analog output signal. It has a maximum 10 bit parallel input signal and a 4 point preset output pressure.  This series is mainly used in combination with the series ITV0000 w/o a display function.
  • Mainly used w/ITV0000 w/o display function
  • Converts digital input signal into analog output
Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Controller for Electro-Pneumatic Regulator Series IC How to Order IC 0 0 1 Pressure range Made to order Standard type Button operation is required for start-up when turning the power supply on again. 1 3 5 9 0.1 MPa Nil 0.5 MPa 0.9 MPa Automatic reset type Automatically returns to the pre-shutdown state when turning the power supply on again. 100 kPa X2 Output specifications 0 1 NPN open

0 IC-0(Built-in sensor type) IC-1(External sensor type) No. q w e r Description Note Breathing port (M3 x 0.5 x 9.5) Breathing port (M3 x 0.5 x 9.5) Power supply, 10 bit input cable 13 cores, O.D. 6.8 mm, 1 m length Cable for 4 point switch output 5 cores, O.D. 6 mm, 1 m length q q Pneumatic regulator connection cable 3 cores, O.D. 3.4 mm, 1 m length Cable for external sensor Note 1) Keep

Pressure Range: 3 (0.5 MPa), Output Specifications: 0 (NPN, Open Collector Output), Sensor: 1 (External Sensor Type), Mounting: A (Panel Mounting)

Pressure Range: 0.5 MPa, Output Specifications: NPN, Open Collector Output, Sensor: External Sensor Type, Mounting: Panel Mounting, Protective Cover: -, Made to Order: -

Series IC, controller for electro-pneumatic regulator converts digital input signal into analog output signal. It has a maximum 10 bit parallel input signal and a 4 point preset output pressure.  This series is mainly used in combination with the series ITV0000 w/o a display function.Mainly used w/ITV0000 w/o display function, Converts digital input signal into analog output signal, 10 bit

Pressure Range: 3 (0.5 MPa), Output Specifications: 0 (NPN, Open Collector Output), Sensor: 0 (Built-in Sensor Type)

Pressure Range: 3 (0.5 MPa), Output Specifications: 0 (NPN, Open Collector Output), Sensor: 0 (Built-in Sensor Type), Mounting: A (Panel Mounting)

Pressure Range: 3 (0.5 MPa), Output Specifications: 0 (NPN, Open Collector Output), Sensor: 0 (Built-in Sensor Type), Mounting: A (Panel Mounting), Protective Cover: B (w/Protective Cover)

Regulator, Pressure Boosting Valve: Controller, Pressure Range: 0.5 MPa, Output Specification: NPN open collector output, Sensor: Built-in sensor type, Mounting specification: None, Protective cover: None

Regulator, Pressure Boosting Valve: Controller, Pressure Range: 0.5 MPa, Output Specification: NPN open collector output, Sensor: Built-in sensor type, Mounting specification: Panel mount, Protective cover: None

Regulator, Pressure Boosting Valve: Controller, Pressure Range: 0.5 MPa, Output Specification: NPN open collector output, Sensor: Built-in sensor type, Mounting specification: Panel mount, Protective cover: With protective cover

Series IC, controller for electro-pneumatic regulator converts digital input signal into analog output signal. It has a maximum 10 bit parallel input signal and a 4 point preset output pressure.  This series is mainly used in combination with the series ITV0000 w/o a display function.Mainly used w/ITV0000 w/o display function, Converts digital input signal into analog output signal, 10 bit

power supply voltage and current signal indication: 1-digit LED indicator (red)LED lights for RUN, CH, SW (red and green)?

Series IC, controller for electro-pneumatic regulator converts digital input signal into analog output signal. It has a maximum 10 bit parallel input signal and a 4 point preset output pressure.  This series is mainly used in combination with the series ITV0000 w/o a display function.Mainly used w/ITV0000 w/o display function, Converts digital input signal into analog output signal, 10 bit

Class: Class 4, Tubing Size: 13 (1/2"x3/8"), Piping, Thread: 1 (Male Thread for Blanking Plug), Packaging: 1 (Tubing Plug Nut Material: PFA; Standard Packaging Equivalent to Class M5.5)

Class: Class 5, Tubing Size: 19 [3/4"x5/8" (ø19 x ø16)], Piping, Thread: 1 (Male Thread for Blanking Plug), Packaging: 1 (Tubing Plug Nut Material: PFA; Standard Packaging Equivalent to Class M5.5)

Class: Class 6, Tubing Size: 25 [1"x7/8" (ø25 x ø22)], Piping, Thread: 1 (Male Thread for Blanking Plug), Packaging: 1 (Tubing Plug Nut Material: PFA; Standard Packaging Equivalent to Class M5.5)