HRW heat exchangers are refrigerant free and use no compressor. This energy efficient design saves further by using an inverter pump for demand-based rotation control. Four models offer cooling capacities from 2 to 30 kW. The HRW is rated for high performance temperature stability of ±0.3°C through a set range of 20 to 90°C. The operation panel includes an input keypad and multi-line LCD display
HRW002-H HRW002-HS HRW008-H HRW008-HS HRW015-H HRW015-HS HRW030-H HRW030-HS Model Water-cooled Cooling method Ambient temperature/humidity Note 1) Temperature: 50 to 95F (10 to 35C), Humidity: 30 to 70%RH FluorinertFC-40/GALDEN HT200 Circulating fluid Note 2) Temperature range setting Note 1) 68 to 194F (20 to 90C) Cooling capacity (50/60 Hz common) (kW) 2 8 15 29 Circulating fluid system
HRW002-H1 HRW002-H1S HRW008-H1 HRW008-H1S HRW015-H1 HRW015-H1S HRW030-H1 HRW030-H1S Model Cooling method Water-cooled Temperature: 50 to 95F (10 to 35C), Humidity: 30 to 70%RH Ambient temperature/humidity Note 1) Circulating fluid Note 2) 60% ethylene glycol aqueous solution 68 to 194F (20 to 90C) Temperature range setting Note 1) Cooling capacity (50/60 Hz common) (kW) 2 8 15 27 Circulating
HRX-OM-K003-I Operation Manual Original Instructions THERMO CHILLER HRW002-H HRW008-H HRW015-H HRW030-H HRW002-H1 HRW008-H1 HRW015-H1 HRW030-H1 HRW002-H2 HRW008-H1 HRW015-H2 HRW030-H2 HRW002-HS HRW008-HS HRW015-HS HRW030-HS HRW002-H1S HRW008-H1S HRW015-H1S HRW030-H1S HRW002-H2S HRW008-H1S HRW015-H2S HRW030-H2S Save This Manual Carefully for Use at Any Time 2021 SMC CORPORATION All Rights
Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type)
Cooling Capacity: 15 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: -
Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type), Option: NZ (N+Z)
Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type), Option: D (DeviceNet Communication)
Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type), Option: N (NPT Fitting)
Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type), Option: Y (DI Control Kit)
Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: S (Pump Inverter Type), Option: DN (D+N)
Cooling Capacity: 15 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: N+Z
Cooling Capacity: 15 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: DeviceNet Communication
Cooling Capacity: 15 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: NPT Fitting
Cooling Capacity: 15 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: DI Control Kit
Cooling Capacity: 15 kW, Type: Ethylene Glycol, Pump Inverter Control: Pump Inverter Type, Option: D+N
Cooling Capacity: 015 (15 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: None, Option: CNZ (C+N+Z)
Cooling Capacity: 015 (15 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: CNZ (C+N+Z)