SMC Corporation of America
Elite Part Number Search
Search Results "HRW008-H2S-DZ"
The HRW series thermo-chiller is a high-performance device for circulating a fluid at a constant temperature (Water-cooled type).  Energy saving is substantially increased by exchanging cooling water and heat directly.  The HRW can achieve reduction in power consumption as it does not have a compressor, and reduction in the amount of facility water used because heat is exchanged directly

HRW heat exchangers are refrigerant free and use no compressor. This energy efficient design saves further by using an inverter pump for demand-based rotation control. Four models offer cooling capacities from 2 to 30 kW. The HRW is rated for high performance temperature stability of ±0.3°C through a set range of 20 to 90°C. The operation panel includes an input keypad and multi-line LCD display

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

HRW002-H HRW002-HS HRW008-H HRW008-HS HRW015-H HRW015-HS HRW030-H HRW030-HS Model Water-cooled Cooling method Ambient temperature/humidity Note 1) Temperature: 50 to 95F (10 to 35C), Humidity: 30 to 70%RH FluorinertFC-40/GALDEN HT200 Circulating fluid Note 2) Temperature range setting Note 1) 68 to 194F (20 to 90C) Cooling capacity (50/60 Hz common) (kW) 2 8 15 29 Circulating fluid system

S HRW002-H2 HRW002-H2S HRW008-H2 HRW008-H2S HRW015-H2 HRW015-H2S HRW030-H2 HRW030-H2S Model Cooling method Water-cooled Temperature: 50 to 95F (10 to 35C), Humidity: 30 to 70%RH Ambient temperature/humidity Note 1) Circulating fluid Note 2) Clear water, Deionized water 68 to 194F (20 to 90C) Temperature range setting Note 1) Cooling capacity (50/60 Hz common) (kW) 2 8 15 30 Circulating fluid

HRX-OM-K003-I Operation Manual Original Instructions THERMO CHILLER HRW002-H HRW008-H HRW015-H HRW030-H HRW002-H1 HRW008-H1 HRW015-H1 HRW030-H1 HRW002-H2 HRW008-H1 HRW015-H2 HRW030-H2 HRW002-HS HRW008-HS HRW015-HS HRW030-HS HRW002-H1S HRW008-H1S HRW015-H1S HRW030-H1S HRW002-H2S HRW008-H1S HRW015-H2S HRW030-H2S Save This Manual Carefully for Use at Any Time 2021 SMC CORPORATION All Rights

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type)

Cooling Capacity: 008 (8 kW), Type: Fluorinated Fluid, Pump Inverter Control: None, Option: DZ (D+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: Z (Circulating Fluid Automatic Recovery)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: D (DeviceNet Communication)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: DY (D+Y)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: Y (DI Control Kit)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: DYZ (D+Y+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: N (NPT Fitting)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: NZ (N+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: YZ (Y+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: DNYZ (D+N+Y+Z)

Cooling Capacity: 008 (8 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: S (Pump Inverter Type), Option: CNYZ (C+N+Y+Z)