HRW heat exchangers are refrigerant free and use no compressor. This energy efficient design saves further by using an inverter pump for demand-based rotation control. Four models offer cooling capacities from 2 to 30 kW. The HRW is rated for high performance temperature stability of ±0.3°C through a set range of 20 to 90°C. The operation panel includes an input keypad and multi-line LCD display
HRW002-H HRW002-HS HRW008-H HRW008-HS HRW015-H HRW015-HS HRW030-H HRW030-HS Model Water-cooled Cooling method Ambient temperature/humidity Note 1) Temperature: 50 to 95F (10 to 35C), Humidity: 30 to 70%RH FluorinertFC-40/GALDEN HT200 Circulating fluid Note 2) Temperature range setting Note 1) 68 to 194F (20 to 90C) Cooling capacity (50/60 Hz common) (kW) 2 8 15 29 Circulating fluid system
Note 10) Weight in the dry state without circulating fluids 112 Thermo-chiller Series HRW Heating Capacity Cooling Capacity HRW002-H2/008-H2/015-H2/030-H2 HRW002-H2S/008-H2S/015-H2S/030-H2S HRW002-H2/008-H2/015-H2/030-H2 HRW002-H2S/008-H2S/015-H2S/030-H2S 0 50 70 90 110 130 150 170F 50 70 90 110 130 150 170 190F 35 7 HRW030-H2 6 30 Heating capacity (kW) Cooling capacity (kW) 5 25 4 20 HRW015
HRX-OM-K003-I Operation Manual Original Instructions THERMO CHILLER HRW002-H HRW008-H HRW015-H HRW030-H HRW002-H1 HRW008-H1 HRW015-H1 HRW030-H1 HRW002-H2 HRW008-H1 HRW015-H2 HRW030-H2 HRW002-HS HRW008-HS HRW015-HS HRW030-HS HRW002-H1S HRW008-H1S HRW015-H1S HRW030-H1S HRW002-H2S HRW008-H1S HRW015-H2S HRW030-H2S Save This Manual Carefully for Use at Any Time 2021 SMC CORPORATION All Rights
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water)
Cooling Capacity: 2 kW, Type: Clean/DI Water, Pump Inverter Control: -, Option: -
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: C (Analog Communication)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: N (NPT Fitting)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: CY (C+Y)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: NZ (N+Z)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: DY (D+Y)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: CN (C+N)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: CNY (C+N+Y)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: NY (N+Y)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: CD (C+D)
Cooling Capacity: 002 (2 kW), Type: 2 (Clean/DI Water), Pump Inverter Control: None, Option: DN (D+N)
Cooling Capacity: 2 kW, Type: Clean/DI Water, Pump Inverter Control: None, Option: Analog Communication
Cooling Capacity: 2 kW, Type: Clean/DI Water, Pump Inverter Control: None, Option: NPT Fitting