SMC Corporation of America
Elite Part Number Search
Search Results "HRW002-H1-C"
Cooling capacity: 2 kW, 8 kW, 15 kW, and 30 kW, Temperature stability: ±0.3 °C, Ideal for ordinary temperature and high temperature processes, Thermo-chiller, Ethylene Glycol Type, THERMO CHILLER, WATER COOLED, 733, 90 lb

HRW heat exchangers are refrigerant free and use no compressor. This energy efficient design saves further by using an inverter pump for demand-based rotation control. Four models offer cooling capacities from 2 to 30 kW. The HRW is rated for high performance temperature stability of ±0.3°C through a set range of 20 to 90°C. The operation panel includes an input keypad and multi-line LCD display

Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

HRW002-H HRW002-HS HRW008-H HRW008-HS HRW015-H HRW015-HS HRW030-H HRW030-HS Model Water-cooled Cooling method Ambient temperature/humidity Note 1) Temperature: 50 to 95F (10 to 35C), Humidity: 30 to 70%RH FluorinertFC-40/GALDEN HT200 Circulating fluid Note 2) Temperature range setting Note 1) 68 to 194F (20 to 90C) Cooling capacity (50/60 Hz common) (kW) 2 8 15 29 Circulating fluid system

(kW) Cooling capacity (kW) 5 25 HRG HRS HRZ HRZD HRW HEC HEB HED Technical Data Related Products 4 20 HRW015-H1 3 15 2 10 HRW008-H1 1 5 HRW002-H1 0 0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 Temperature difference t (C) (Circulating fluid temperature Facility water temperature) Circulating fluid temperature (C) Pump Capacity HRW002-H1 HRW002-H1S Circulating fluid: 60% ethylene

HRX-OM-K003-I Operation Manual Original Instructions THERMO CHILLER HRW002-H HRW008-H HRW015-H HRW030-H HRW002-H1 HRW008-H1 HRW015-H1 HRW030-H1 HRW002-H2 HRW008-H1 HRW015-H2 HRW030-H2 HRW002-HS HRW008-HS HRW015-HS HRW030-HS HRW002-H1S HRW008-H1S HRW015-H1S HRW030-H1S HRW002-H2S HRW008-H1S HRW015-H2S HRW030-H2S Save This Manual Carefully for Use at Any Time 2021 SMC CORPORATION All Rights

Cooling Capacity: 002 (2 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: None, Option: CNY (C+N+Y)

Cooling Capacity: 002 (2 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: None, Option: CD (C+D)

Cooling capacity: 2 kW, 8 kW, 15 kW, and 30 kW, Temperature stability: ±0.3 °C, Ideal for ordinary temperature and high temperature processes, Thermo-chiller, Ethylene Glycol Type, THERMO CHILLER, WATER COOLED, 733, 90.00000 lb

Cooling capacity: 2 kW, 8 kW, 15 kW, and 30 kW, Temperature stability: ±0.3 °C, Ideal for ordinary temperature and high temperature processes, Thermo-chiller, Ethylene Glycol Type, THERMO CHILLER, WATER COOLED, 733, 90 lb

Cooling Capacity: 002 (2 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: None, Option: N (NPT Fitting)

Cooling Capacity: 002 (2 kW), Type: 1 (Ethylene Glycol), Pump Inverter Control: None, Option: Y (DI Control Kit)