HRSH Air-cooled recirculating chillers offer a cooling capacity range of 10.5 to 28 kW. Coolant and refrigeration circuits are included in a compact and lightweight package. Extracted heat is air cooled. An inverter provides demand-based rotation control for the compressor, pump and fan, offering substantial energy savings. Electric options ensure global power supply compatibility. Additional
Power supply 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Specications Model HRSH100-Al-20-l HRSH150-Al-20-l HRSH200-Al-20-l HRSH250-Al-20-l HRSH300-Al-20-l Cooling method Air-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.27 2.1 2.1 2.8 2.8 Control method PID control Ambient temperature/Altitude Note 1), 9) C Temperature: 20 to 45, Altitude: less than 3000
Lifting height [m] Pressure [MPa] Lifting height [m] Circulating fluid flow rate [LPM] Circulating fluid flow rate [LPM] Required Facility Water Flow Rate HRS050-A-20 (Single-phase 200 to 230 VAC) 0.5 10 20 10 20 50 HRS012-W, HRS018-W, HRS024-W-20 Outlet 60 [Hz] 0.4 40 Facility water flow rate [L/min] 30 0.3 30 25 Outlet 60 [Hz] HRS024-W-20 20 0.2 20 10 20 HRS018-W15 10 0.1 Return port 10
This is included in the response from the product when there is an error in the received request. 9 NAK(15h) Error content is included in the response when there is an error in the received request. Refer to the table below for exception codes.
Similar items in stock.
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting)
Cooling Capacity: 20.5 kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: -
Cooling Capacity: 200 (20.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: KS (K + S)
Cooling Capacity: 20.5kW, Thread: NPT, w/Rc-NPT Conversion Fitting, Option: K + S
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AB1K (A + B1 + K)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKS (A + K + S)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: ABK (A + B + K)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AS (A + S)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: K (w/Fluid Fill Port)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: S (Conforming to CE/UL Standards)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: ABW (A + B + W)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AK (A + K)
Cooling Capacity: 200 (20.5 kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: BKW (B + K + W)