SMC Corporation of America
Elite Part Number Search
Search Results "HRS090-WN-20-JM"
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
The HRS090 is a compact chiller with large cooling capacity. A 9.0kW air cooled or 10.5kW water cooled refrigeration circuit can be selected. The chiller package also contains the coolant circuit, including pump, tank, heat exchanger, and sensor monitored flow path. Set temperatures are PID controlled, while the system is monitored for 41 alarms. Additional features include a heating function,
Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Lifting height [m] Pressure [MPa] Lifting height [m] Circulating fluid flow rate [LPM] Circulating fluid flow rate [LPM] Required Facility Water Flow Rate HRS050-A-20 (Single-phase 200 to 230 VAC) 0.5 10 20 10 20 50 HRS012-W, HRS018-W, HRS024-W-20 Outlet 60 [Hz] 0.4 40 Facility water flow rate [L/min] 30 0.3 30 25 Outlet 60 [Hz] HRS024-W-20 20 0.2 20 10 20 HRS018-W15 10 0.1 Return port 10

-A-20. 9-1 9.1.2 HRS090-A-40. 9-2 9.1.3 HRS090-A-46. 9-3 9.1.4 HRS090-W-20. 9-4 9.1.5 HRS090-W-40. 9-5 9.1.6 HRS090-W-46. 9-6 9.1.7 Refrigerant with GWP reference . 9-7 9.1.8 Communication specification . 9-7 9.2 Outline dimensions . 9-8 9.2.1 HRS090-A-20/40/46-. 9-8 9.2.2 HRS090-W-20/40/46-. 9-9 9.3 Flow diagram . 9-10 9.3.1 HRS090-A-20/40/46-. 9-10 9.3.2 HRS090-W-20/40/46 . 9-10 9.4 Cooling

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: JM (J + M)

Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J + M

Cooling Method: Water-cooled Refrigeration, Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J + M

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Capacity: 9 kW, Piping thread type: NPT (Rc-NPT conversion fitting included), Optional specifications: None

Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: 050 (Cooling Capacity: 4700/5100W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: JM (J + M)