SMC Corporation of America
Elite Part Number Search
Search Results "HRS090-WF-46"
the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, WATER COOLED, HRS090
The HRS090 is a compact chiller with large cooling capacity. A 9.0kW air cooled or 10.5kW water cooled refrigeration circuit can be selected. The chiller package also contains the coolant circuit, including pump, tank, heat exchanger, and sensor monitored flow path. Set temperatures are PID controlled, while the system is monitored for 41 alarms. Additional features include a heating function,
Configure Options...

CAD Downloads

CAD FILES FROM ETECH

View CAD Models

View 3D Model

Product Catalog

Series Catalog

RoHS Certificate

Download Certificate

Information Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN http://www.smcworld.com 2011 SMC Corporation All Rights Reserved 10-E569 D-DN Printing PQ 12450SZ Circulating Fluid Temperature Controller Thermo-chiller Compact Type Series HRS 4700 W/5100 W (50/60 Hz) cooling capacity added! (HRS050) (Except HRS050) RoHS Compact/ Space-saving Lightweight Weight 69 kg HRG

-A-20. 9-1 9.1.2 HRS090-A-40. 9-2 9.1.3 HRS090-A-46. 9-3 9.1.4 HRS090-W-20. 9-4 9.1.5 HRS090-W-40. 9-5 9.1.6 HRS090-W-46. 9-6 9.1.7 Refrigerant with GWP reference . 9-7 9.1.8 Communication specification . 9-7 9.2 Outline dimensions . 9-8 9.2.1 HRS090-A-20/40/46-. 9-8 9.2.2 HRS090-W-20/40/46-. 9-9 9.3 Flow diagram . 9-10 9.3.1 HRS090-A-20/40/46-. 9-10 9.3.2 HRS090-W-20/40/46 . 9-10 9.4 Cooling

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option: JM (J + M)

the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, THERMO-CHILLER, WATER COOLED, HRS090

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]

Cooling Method: Water-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: -

Cooling Method: Water-cooled Refrigeration, Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)]