HRS compact recirculating chillers are designed to meet the widest range of single-point applications in both industrial and technology settings. The package design is robust enough for the factory, yet ergonomic and compact for lab installations. Coolant can be either heated or cooled within the set temperature range. Choose from six cooling capacities, air or water cooled refrigerant, and
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
HRS012-A-10 HRS012-W-10 HRS018-A-10 HRS018-W-10 Model Cooling method Refrigerant Control method Ambient temperature/humidity Note 2) Air-cooled refrigeration Water-cooled refrigeration Air-cooled refrigeration Water-cooled refrigeration R407C (HFC) PID control Temperature: 5 to 40C, Humidity: 30 to 70% Clear water, 15% ethylene glycol aqueous solution Note 5) Circulating fluid Note 3) Circulating
HRX-OM-M091-P Operation Manual Communication function Thermo chiller Air-Cooled Water-Cooled refrigerated type refrigerated type HRS012-A-10HRS012-W-10HRS018-A-10HRS018-W-10HRS012-A-20HRS012-W-20HRS018-A-20HRS018-W-20HRS024-A-20HRS024-W-20HRS030-A-20HRS030-W-20HRS040-A-20 HRS040-W-20HRS050-A-20HRS050-W-20HRS060-A-20HRS060-W-20Keep this manual available whenever necessary 2022 SMC CORPORATION
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-pressure Pump)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-pressure Pump)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: T (High-pressure Pump)
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: T (High-pressure Pump)
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: High-pressure Pump
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: High-pressure Pump
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: High-pressure Pump
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: High-pressure Pump
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc
Cooling Capacity: Cooling Capacity: 1500/1700W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: -
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: T (High-lift Pump)
Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: High pump head specification
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS018-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Cooling Capacity: 018 (Cooling Capacity: 1500/1700W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJM (B + J + M)